    Whole-Genome Amplification of Respiratory Syncytial Virus (RSV) using Illumina CovidSeq reagents for Next-Generation Sequencing

    Carlos Davina-Nunez, Sonia Perez-Castro, Montse Godoy-Diz, Benito Regueiro-Garcia

    Published: 2023-08-02 DOI: 10.17504/protocols.io.eq2lyjzbrlx9/v2
    AI 解读
    浏览 1643

    Disclaimer

    Abstract

    This protocol has been tested for amplification of RSV-positive nasopharyngeal swabs of CT value up to 24 using Seegene Allplex Respiratory Panel (Seegene Inc, Seoul, South Korea). This protocol does not require prior subtyping as it covers RSV-A and RSV-B in the same reaction. Panel of primers is an optimisation of a previously published panel by Wang et al.

    This panel was modified to optimise the multiplex PCR, so the whole genome can be amplified in just two PCR reactions. In addition to this, primers have been modified to account for commonly-occurring mutations in the 22-23 season that affect primer-binding areas and were causing suboptimal amplification.

    These primers were used to cover the complete hRSV genome (both A and B) by splitting into two pools of non-consecutive amplicons (odd-numbered amplicon primers in one pool, even-numbered amplicon primers in other). This allowed for Whole-genome amplification in two reactions.

    Illumina CovidSeq (Illumina Inc, San Diego, USA) reagents were used for the RT-PCR, with a mix previously published for amplification of Influenza RNA and a thermocycling program optimised in our lab. The library preparation part of the protocol was performed according to the Illumina CovidSeq protocol.

    Before start

    This protocol uses as input RNA extracted from nasopharyngeal swabs after confirmation of RSV infection via RT-PCR. Samples were extracted using the QIASymphony DSP Virus/Pathogen Midi Kit (Qiagen, Hilden, Germany).

    Steps

    Primer pools preparation

    1.

    Prepare both primer mixes according to Table 1.

    For a final concentration of 10uM: add 1017 ul of Nuclease-Free water to Pool 1 and 1035 ul to Pool 2.

    ABCDEF
    A1f5WangACGSGAAAAAATGCGTACAAC11
    A1r5WangGAAGATTGTGCTATACCAAAATGAACA17791
    AB3f10GoyaGCYATGGCAAGACTYAGGAATG28971
    A3r5WangGTTTGCYGAGGCTATGAATATGAT48261
    A5f5WangGAACAACAGACTACTAGAGATTACCAG63741
    A5r10This publicationAGGAGTTTRCTCATRGCAA79291
    A7f5WangAGCTTAGGCTTAAGATGYGGA94231
    A7r5WangTGAGTTTGACCTTCCATGAGT109971
    A9f7WangGGGTTGGTTCATCTACACAAGAG123161
    A9r7This publicationCGCAATAATAAATTCCCTGCTCC140941
    B1f5WangACGCGAAAAAATGCGTACTACA11
    B1r5WangCATTGTTTGCCCTCCTAATTACTG16611
    B3r5WangATAGGGCCAAAATTTGCTTGTG43091
    B5f5WangAGTGCAATCTTCCTAACTCTTGC57001
    B5r5WangTGATTCCACTTAGTTGGTCTTTGC73751
    B7f5WangGGTGAACTGAAATTAGAAGAACCAAC87601
    B7r5WangCACCATATCTTGTCAAACTCTCAGG105071
    B9f7WangGAACCAACTTACCCTCATGGATT118601
    B9r7WangTTCTGGGGTTGGGTGATATAG136501
    A2f5WangACAGGCATGACTCTCCTGAT15562
    A2r5WangTTGGGTGTGGATATTTGTTTCAC34002
    A4f5WangACCTGGGACACTCTCAATCA46972
    A4r5WangGACATGATAGAGTAACTTTGCTGTCT65402
    A6f5WangGTCACGAAGGAATCCTTGCA76422
    A6r5WangCCCTCTACCTCTTTTATTATGTAGAACC95212
    A8f5WangGGTGTACAATCTCTATTTTCCTGGT107042
    A8r5WangCGATTAATAGGGCTAGTATCAAAGTG126152
    A10f10This publicationCRTCTACAATGATTAGAACCAATTAC137422
    A10r10WangACGAGAAAAAAAGTGTCAAAAACTAA152252
    B2f5WangCAGRTTAGGAAGGGAAGACACTA13162
    B2r5WangCAAGTCACTCAATTTTTTGGAGGTTGG29822
    B4f10WangTGGAAGCAYACAGCTACACG39432
    B4r10WangCTACATGTYGATTGGTAAAACTCC57882
    B6f5WangCCTCTAGTGTTTCCTTCTGATGAG71132
    B6r5WangGTTGTAGCAATTTGTTCAGACGAG88342
    B8f5WangAAGTTCTCTGAAAGCGACAGATC102312
    B8r5This publicationTAATACTWGGTGATGTTACTCCTAC121902
    B10f5WangTAGTCAATCAAGACACAAGTTTGC132892
    B10r5WangACGAGAAAAAAAGTGTCAAAAACTAATG152222

    Table 1: mix of primers used for amplification. Two mixes are required, one for pool 1 and another for pool 2. References for base number: hRSV/A/England/397/2017 and hRSV/B/Australia/VIC-RCH056/2019 for RSV-A and RSV-B respectively. Citation to the original papers for the primers can be found below.

    RT-PCR

    2.

    Two Master Mixes must be prepared per sample: one for Pool1 and one for Pool 2 (Table 2). Manipulate reagents according to the Illumina CovidSeq Reference Guide.

    ABC
    IPM1515
    FSM3.23.2
    RVT11
    Nuclease-Free Water3.63.6
    Primer pool 1 (10uM)1.2-
    Primer pool 2 (10uM)-1.2

    Table 2: Master mixes required for amplification of the RSV genome. Reaction 1 targets odd-numbered amplicons while reaction 2 targets even-numbered amplicons.

    In a PCR tube, mix 20 ul of MasterMix with 5 ul of extracted RNA.

    Place all tubes (two per sample) in a thermocycler and run the following program (Table 3):

    ABC
    42º60 min
    98º2 min
    98º15 s35 cycles
    63º7 min
    4ºPAUSE

    Table 3: Thermocycler program for RT-PCR. Indicate 25 ul as volume and heat lid at 99ºC.

    (OPTIONAL) Check RT-PCR result with Agilent Bioanalyzer

    3.

    Use an Agilent Bioanalyzer to check for amplification peaks. Expect PCR peaks around ~2000 bps.

    Citation
    RT-PCR result: peaks expected around 2000 bps. Representative image of an Agilent bioanalyzer of the amplification products. From left to right: ladder; RSV-A, pool 1; RSV-A, pool 2; RSV-B, pool 1; RSV-B, pool 2. Scale indicates size in base pairs.
    RT-PCR result: peaks expected around 2000 bps. Representative image of an Agilent bioanalyzer of the amplification products. From left to right: ladder; RSV-A, pool 1; RSV-A, pool 2; RSV-B, pool 1; RSV-B, pool 2. Scale indicates size in base pairs.

    Library preparation

    4.

    Mix 10ul of tube one and tube two on each sample for a final 20 ul of PCR product. Follow instructions of the Illumina CovidSeq Reference Guide to generate sequencing-ready libraries.

    Recommended: To ensure optimal normalisation, perform the library Clean-up on each tube and normalise individually instead of pooling. This improves normalisation especially in the presence of low-concentration PCR products.

    Quantify samples after Clean-up using Qubit Flex and normalise samples.

    (OPTIONAL): Check library preparation on an Agilent Bioanalyzer. The pattern expected is the usual post-tagmentation pattern from Illumina libraries with the highest peak around ~330bps.

    Expected results

    5.

    Coverage obtained after an iSeq run with 16 samples: 8 from RSV-A, 7 from RSV-B and a negative control.

    Average reads per sample (excluding negative control): 361k

    Citation
    #尊敬的用户,由于网络监管政策的限制,部分内容暂时无法在本网站直接浏览。我们已经为您准备了相关原始数据和链接,感谢您的理解与支持。http://lh4.googleusercontent.com/FjwTBcX_2JHv13sPkhkt3o2DifOTneaG7w2xTRCkyQewtJDXo1AktipKlNhA7l5HBCJDfWaBxc_-gEVI2UduryGuiPAhbn0I6Y4JFLoTB06tIKDM4M5-pZ5xh_IymoKgnoE0yXfgFIX9b7gSc4aAHEM

    References

    6.

    The illumina CovidSeq protocol can be found in:

    Illumina CovidSeq Reference Guide

    The primers found in Table 1 were obtained from:

    Citation
    Wang L, Ng TFF, Castro CJ, Marine RL, Magaña LC, Esona M, Peret TCT, Thornburg NJ 2022 Next-generation sequencing of human respiratory syncytial virus subgroups A and B genomes. http://doi.org/10.1016/j.jviromet.2021.114335

    Citation
    Stephanie Goya, Gabriel L. Rojo, Mercedes S. Nabaes Jordar, Laura E. Valinotto, Alicia S Mistchenko, Mariana Viegas Whole genome sequencing of respiratory syncytial (RSV) virus from clinical samples with low viral load protocols.io http://protocols.io/view/whole-genome-sequencing-of-respiratory-syncytial-r-bmhak32e

    The Master Mix used for RT-PCR with Illumina CovidSeq was first published in:

    Citation
    Ying Lin, Jeffrey Koble, Priyanka Prashar, Anita Pottekat, Christina Middle, Scott Kuersten, Michael Oberholzer, Robert Brazas, Darcy Whitlock, Robert Schlaberg, Gary P. Schroth A sequencing and subtyping protocol for Influenza A and B viruses using Illumina® COVIDSeq™ Assay Kit protocols.io http://protocols.io/view/a-sequencing-and-subtyping-protocol-for-influenza-crv3v68n